Material Specification:
UltraCure NCF™ moisture-retaining covering by McTech Group, Inc. is a natural colored cellulose fabrics with a 3 mil
white reflective impervious coating applied to one side designed to help provide protection against UV degradation. The
non-staining fabric has a tensile strength meeting ASTM D- 882 and a minimum retention capacity of 6.5(g). Material
shall meet or exceed ASTM C171-03, ASTM C171-97a and AASHTO M171-00, standard specifications for sheet
material for curing concrete slabs or pavement.
Application:
Place wet, UltraCure NCF™ wet cure covering in widest practical width as soon as concrete has hardened sufficiently to
prevent surface damage. Sides and end shall be lapped at least 3″. Immediately repair any holes or tears during curing
period using wet cure material and water. Cover entire surface area including edges of paving and sidewalks. Install
UltraCure NCF™ moisture containing wet cure covering material as per manufacturer’s written instructions. Wet surface
of slab on-grade with 1/8″ to 1/4″ inch of water to cover entire surface area of slab, then slowly unroll the UltraCure
NCF™ product onto slab using the roller squeegee applicator. No portion of this product shall be reused once it has been
put into use on a slab on grade or other concrete application. Maintain UltraCure NCF™ in place on concrete for a period
of not less than seven (7) days after placement. Continuous inspection for the purpose of maintaining 100 % curing
blanket contact with surface to be cured is recommended.
Valoraciones